Skip to main content
. Author manuscript; available in PMC: 2010 Sep 1.
Published in final edited form as: J Cardiovasc Electrophysiol. 2009 Sep;20(9):1048–1054. doi: 10.1111/j.1540-8167.2009.01475.x

Table 1.

Summary of AP parameters of control, singly- and co-transduced LV CMs. All values are means ± S.E.

RMP
(mV)
MDP
(mV)
APD
(ms)
APD50
(ms)
APD90
(ms)
Phase 4
Length
(ms)
Phase 4
Slope
(mV/s)
Cycle
Length
(ms)
Beating
Rate
(Beats/
min)
Control
(17)
-66.0
±
0.7
-- 387.2
±
10.4
299.5
±
12.0
357.3
±
10.0
-- -- -- --
Kir 2.1
(7)
-69.7
±
0.6
-- 138.6
±
17.6
116.1
±
17.2
127.8
±
17.8
-- -- -- --
HCN1-ΔΔΔ
(10)
-- -55.8
±
1.8
207.4
±
9.4
166.9
±
6.9
199.5
±
8.7
88.3
±
9.6
180.0
±
20.0
343.7
±
24.9
181.1
±
13.1
HCN1-ΔΔΔ +
Kir2.1-WT
(9)
-- -57.1
±
1.0
107.37
±
7.8
72.7
±
7.8
97.3
±
7.9
55.0
±
4.5
280.0
±
16.0
182.3
±
6.8
320.0
±
15.8

n numbers are given in bracket.