Skip to main content
. Author manuscript; available in PMC: 2010 Aug 1.
Published in final edited form as: Am J Cardiol. 2009 Jun 6;104(3):419–428. doi: 10.1016/j.amjcard.2009.03.058

Table 4.

Comparison between echocardiography and CMR measurements in 124 subjects

Variable Echo CMR Mean Difference (95% CL) Mean Ratio (95% CL)

Mean ± SD (range) Median Mean ± SD (range) Median
LV EDV (ml) 76.8 ± 46.3 (6.8, 289.6) 62.8 97.5 ± 45.8 (11.1, 233.2) 94.0 −20.7 (−86.6, 45.1) 0.76 (0.40, 1.47)
LV ESV (ml) 31.9 ± 27.1 (3.3, 214.7) 24.9 41.1 ± 22.5 (2.0, 114.9) 38.3 −9.3 (−51.3, 32.7) 0.73 (0.27, 1.95)
LV EF (%) 59.9 ± 10.8 (25.9, 85.3) 61.0 58.3 ± 9.4 (29.3, 91.0) 58.6 1.6 (−23.3, 26.5) 1.02 (0.65, 1.61)
LV mass (g) 88.2 ± 55.9 (11.9, 332.8) 68.2 84.8 ± 47.5 (19.0, 273.9) 76.2 3.4 (−74.3, 81.1) 1.00 (0.48, 2.08)
RV EDV (ml) 71.6 ± 39.1 (15.1, 203.0) 67.1 101.9 ± 44.4 (38.5, 213.0) 93.0 −30.3 (−83.5, 23.0) 0.67 (0.34, 1.33)
RV ESV (ml) 31.5 ± 23.7 (6.3, 138.3) 24.1 44.4 ± 24.9 (9.9, 125.2) 38.7 −12.9 (−50.0, 24.2) 0.66 (0.25, 1.74)
RV EF (%) 56.9 ± 11.0 (26.2, 76.8) 56.2 56.7 ± 9.5 (8.6, 76.1) 55.5 0.2 (−24.2, 24.6) 1.00 (0.65, 1.53)
RV mass (g) 84.7 ± 47.2 (14.6, 237.7) 67.8 86.2 ± 48.0 (29.6, 230.4) 74.6 −1.4 (−55.1, 52.2) 0.97 (0.47, 1.98)

N = 83 for LV comparisons, N=53 for RV comparisons

CL: confidence limits; CMR: cardiac magnetic resonance; EDV: end-diastolic volume; ESV: end-systolic volume; g: grams; ml: milliliters; LV: left ventricle; RV: right ventricle; SD: standard deviation