Skip to main content
. 2009 Jul;138(1):84–88. doi: 10.1016/j.jtcvs.2008.08.072

Table 2.

Functional outcome

Parameter Before After P value
Cardiac magnetic resonance imaging
 Pulmonary regurgitant fraction (%) 20 ± 6 2 ± 1 <.05
 RV end-diastolic volume (mL · beat−1 · m−2) 91 ± 13 78 ± 12 <.01
 RV end-systolic volume (mL · beat−1 · m−2) 41 ± 10 34 ± 11 .06
 Effective RV stroke volume (mL · beat−1 · m−2) 39 ± 3 43 ± 2 .11
 RV ejection fraction (%) 59 ± 4 62 ± 5 .43
Cardiopulmonary exercise testing
 Peak oxygen consumption (mL · kg−1 · min−1) 25.4 ± 2.3 30.8 ± 3.0 <.01
 Maximum workload (W) 128 ± 11 150 ± 13 <.01
 Anaerobic threshold (mL · kg−1 · min−1) 13.6 ± 1.3 15.0 ± 1.3 <.05
 Respiratory exchange ratio 1.10 ± 0.04 1.10 ± 0.02 .95

All data are mean ± SEM. RV, Right ventricle.