Table 2.
Component | Specification |
---|---|
Laser sensor (ZX-LD40, OMRON) | Diffusional reflection type, DC Power Detection length: 40 ± 10 mm Resolution: 2 μm Wavelength: 650 nm Power: 1 mW |
Valve | Three-way solenoid valve |
Pump | 12 V, DC power |
DAQ (USB, National Instrument) | 14-bit, 48 kS/s Multifunction I/O and NI-DAQmx |