Table 1.

Luminescence Decay Parameters for rac–, Δ– and Λ–Ru(bpy)2dppz2+ with DNAa

Complex DNA τ1 (ns)b τ2 (ns)b τ1:τ2b
rac-Ru Matched 72 212 83:17
Mismatched 74 213 77:23
Abasic 86 192 69:31
Δ-Ru Matched 83 245 88:12
Mismatched 91 296 86:14
Abasic 90 204 79:21
Λ-Ru Matched 41 199 89:11
Mismatched 37 156 78:22
Abasic 69 167 41:59
a

Samples containing 10 μM Ru and 20 μM DNA (5 mM Tris, pH 7.5, 50 mM NaCl) were used for the excited state lifetime measurements (λex = 470 nm, λem = 610 nm). The 27-mer oligonucleotides (matched, mismatched and abasic DNA, Figure 2) were used.

b

Uncertainties in excited state lifetimes are ≤ 10%.

c

Relative contributions of each lifetime to the overall decay.