Skip to main content
. Author manuscript; available in PMC: 2009 Sep 30.
Published in final edited form as: Opt Express. 2009 Aug 17;17(17):14599–14617. doi: 10.1364/oe.17.014599

Table 1.

Chromophore concentrations of dorsal forearm of 18 subjects recovered with two-regional fitting. Standard deviations were calculated to illustrate the deviation of recovered chromophore concentrations of 6 subjects within each group. Res.full represents the fitting residual of full wavelength range (500–1000nm) fitting, and Res.reg represents the fitting residual of two-regional fitting.

500–600nm 600–1000nm



Dorsal
forearm
deoxyHb
[µM]
oxyHb
[µM]
Melanin
[%]
deoxyHb
[µM]
oxyHb
[µM]
Melanin
[%]
H2O
[%]
Lipid
[%]
Res.
full
Res.
Reg
I–II 0.26
±0.19
0.81
±0.42
1.65
±0.18
0.12
±0.51
7.74
±3.15
0.87
±0.18
21.42
±2.59
27.74
±5.01
0.00165 0.00066
III–IV 0.31
±0.28
0.84
±0.30
1.98
±0.09
0.08
±0.26
9.47
±3.41
1.15
±0.09
22.46
±2.46
26.12
±6.04
0.00149 0.00069
V–VI - - - 0.02
±0.10
2.72
±2.40
1.65
±0.23
18.66
±3.17
16.56
±8.23
- 0.00104