Skip to main content
. 2009 Jul 21;53(7):677–689. doi: 10.1093/annhyg/mep046

Table 3.

BZCs (μg m−3) of monomeric and polymeric HDIa for samples collected in NC and WA stratified by sampler type

Analyte NC
WA
Nb GM GSD Range Nb GM GSD Range
HDI 88 3.21 6.05 0.003–179 200 4.56 5.10 0.0007–65.5
    One stage 19 1.54 5.26 0.003–10.7 78 9.49 2.96 0.009–60.3
    Two stage 69 3.93 6.00 0.01–179 122 2.85 5.79 0.0007–65.5
Uretidone 88 1.68 27.2 0.002–1430 200 2.35 15.2 0.0004–613
    One stage 19 0.84 7.29 0.002–62.6 78 7.02 11.8 0.004–613
    Two stage 69 2.04 33.9 0.003–1430 122 1.16 13.8 0.0004–266
Biuret 88 2.58 11.4 0.01–7720 200 12.8 12.4 0.003–1020
    One stage 19 3.17 6.07 0.08–70.0 78 24.3 8.22 0.03–1020
    Two stage 69 2.44 13.7 0.01–7720 122 8.5 15.3 0.003–734
Isocyanurate 88 958 6.05 4.09–17 800 200 1670 3.96 0.09–18 700
    One stage 19 825 4.74 17.8–3190 78 2160 3.67 0.68–18 700
    Two stage 69 1000 6.48 4.09–17 800 122 1420 4.06 0.09–14 600

GSD, geometric standard deviation.

a

Multiple imputation (n = 10 imputed datasets) was used to impute air-sampling data below detection limits.

b