Skip to main content
. Author manuscript; available in PMC: 2010 Nov 1.
Published in final edited form as: Exp Neurol. 2009 Aug 3;220(1):57–70. doi: 10.1016/j.expneurol.2009.07.023

Fig. 10. Pulse train HFS Conduction Block is Amplitude Dependent.

Fig. 10

A. Conduction block is amplitude dependent, with complete block occurring at higher stimulus amplitudes. B. Stimulation paradigm in-vitro. C. The threshold current for complete block is significantly larger than the stimulus amplitude at which evoked responses fail to follow pulse train HFS (405 ± 101 μA, 101 ± 46 μA, respectively, p<0.0001, Student's 2 sample t test).