Skip to main content
. Author manuscript; available in PMC: 2010 Sep 1.
Published in final edited form as: Clin Cancer Res. 2009 Aug 25;15(17):5478–5484. doi: 10.1158/1078-0432.CCR-08-2704

Table 2.

Concordance of PKA scores obtained from manual and semiautomated image (ACIS) analysis

Manual Image analysis
KS (P)*
<Q1 (101.7), n (%) ≥Q1 (101.7), n (%)
Negative (0, 1) 77 (25) 103 (33)
Positive (2, 3) 1 (<1) 132 (42) 0.38 (<0.0001)
Low (0, 1, 2) 78 (25) 176 (56)
High (3) 0 59 (19) 0.14 (<0.0001)
<Median (111.8) ≥Median (111.8)

Negative (0, 1) 144 (46) 36 (12)
Positive (2, 3) 12 (4) 121 (39) 0.69 (<0.0001)
Low (0, 1, 2) 156 (50) 98 (31)
High (3) 0 59 (19) 0.38 (<0.0001)
<Q3 (128.0) ≥Q3 (128.0)

Negative (0, 1) 177 (57) 3 (1)
Positive (2, 3) 57 (18) 76 (24) 0.59 (<0.0001)
Low (0, 1, 2) 229 (73) 25 (8)
High (3) 5 (2) 54 (17) 0.72 (<0.0001)
<135.5 ≥135.5

Negative (0, 1) 178 (57) 2 (<1)
Positive (2, 3) 80 (26) 53 (17) 0.42 (<0.0001)
Low (0, 1, 2) 240 (77) 14 (4)
High (3) 18 (6) 41 (13) 0.66 (<0.0001)
*

KS = κ statistic and P values are from two-sided tests.