Skip to main content
. 2009 Jul 28;297(4):E849–E855. doi: 10.1152/ajpendo.90996.2008

Table 3.

Euglycemic hyperinsulinemic clamp

Methods Checklist Considerations in Experimental Design Recommendations for Data Presentation
Body composition and, if possible, body composition Fast duration Present entire time course of glucose concentrations and glucose infusion rates
Sex, age, and littermates, if used Hematocrit changes if hand-held blood glucose meters are used Present absolute rates of endogenous glucose production
Complete protocol for insulin and tracer infusion, including any priming boluses that are used Group differences in body weight and body composition when insulin dose is calculated Present actual basal and clamp plasma insulin concentrations
Flux calculations when appropriate Predicted volumes of distribution and fractional turnover rates of insulin and glucose and predicted steady-state values when priming doses are calculated
Route of glucose, insulin and tracer administration
Blood sampling sites and frequency of collection
Indicate if restraint or anesthesia was used
Diet and fasting status
Alterations in environment (temperature, light-dark cycle)

Considerations and recommendations are those specified by the authors. Adapted from Wasserman et al. (27), with permission.