Table 2.

Specific stimulation parameters used to record the individual responses shown in Figure 2 and 3 are listed. Also listed are the response latencies and peak to peak amplitudes for each subject. Electrode 1 refers to the electrode used for stimulation during the first 300 ms of the experimental trials. Electrode 2 is the stimulating electrode used in the second 300 ms of the experimental trials.

Stimulation Parameters Onset Response EACC
Subject
ID
Rate
used
for
T&C
levels
Electrode 1 Electrode 2 EP
Stimulus
Level
N1
latency
(ms)
P2
latency
(ms)
N1-P2
amplitude
(µV)
N1
latency
(ms)
P2
latency
(ms)
N1-P2
amplitude
(µV)
E1 T-level C-
level
E2 T-level C-
level
M66 1000Hz 10 DNT 222 15 DNT 222 222 95.0 195.0 12.00 92.0 188.0 6.37
M54L 1200Hz 5 164 225 10 170 232 225 102.0 185.0 8.17 105.0 184.0 5.83
M58R 720Hz 10 133 175 15 130 169 170 118.0 196.0 5.25 112.0 195.0 2.69
M52L 720Hz 10 149 218 15 150 218 205 112.0 216.0 6.47 108.0 183.0 3.15
M52R 720Hz 10 146 215 15 152 222 205 116.0 206.0 5.18 100.0 209.0 2.43
R13 1000Hz 14 DNT 185 19 DNT 189 185 125.0 259.0 5.45 114.0 266.0 4.31
R15 900Hz 17 155 207 21 157 206 205 120.0 184.0 3.69 108.0 173.0 2.75
R80 900Hz 15 134 204 20 135 201 210 134.0 224.0 6.85 119.0 191.0 2.39
R82 1000Hz 15 DNT 205 20 DNT 207 205 129.0 212.0 5.99 118.0 245.0 3.16
R47R 900Hz 10 121 181 15 119 184 180 107.0 211.0 3.13 114.0 207.0 1.59
Mean 115.8 208.8 6.22 109.0 204.1 3.47
S.E. 3.84 6.96 0.79 2.64 9.35 0.49