Skip to main content
. Author manuscript; available in PMC: 2010 Mar 1.
Published in final edited form as: J Am Soc Mass Spectrom. 2008 Nov 17;20(3):435–442. doi: 10.1016/j.jasms.2008.10.024

Table 1.

Charge State Assignment Methods, Number of correct assignments
Complex (Buffer) [Collision energy] R2 Absolute value of the slope Conventional ESI First positive slope Replicates
SsDps-L (TEAA pH 6.8) [CE 50] 1 2 0 3 3
SsDps-L (AA pH 6.8) [CE 50] 1 3 3 3 3
SsDps-L (AA pH 8.2) [CE 50] 0 3 3 3 3
SsDps-L (AB pH 6.8i 7.4f) [CE 50]* 1 0 3 3 3
SsDps-L (AB pH 8.3) [CE 50]** 3 0 3 3 3
SsDps-L (TEAA pH 8.3i 7.7f) [CE 50]* 0 1 0 2 2
LiDps (AA pH6.8) [CE 50] 1 3 3 3 3
LiDps (AB pH8.2) [CE 50] 0 3 3 3 3
LiDps (AA pH8.7) [CE 50] 0 3 3 3 3
LiDps (TEAA pH8.3) [CE 50] 1 3 2 3 3
LiDps (TEAA pH6.8) [CE 50] 2 2 2 2 2
LiDps (TEAA pH 6.8) [CE 30] 0 3 3 3 3
LiDps (TEAA pH 6.8) [CE 50] 1 3 3 3 3
LiDps (TEAA pH 6.8) [CE 70] 2 3 3 3 3
LiDps (TEAA pH 6.8) [CE 90] 2 2 2 2 2
LiDps (TEAA pH 6.8) [CE 110] 1 2 2 2 2
LiDps (TEAA pH 6.8) [CE 130] 0 1 2 2 2
All Data Correct for 35% Correct for 80% Correct for 87% Correct for 100% 46
*

“i” indicates the pH prior to injection of the first replicate and “f” indicates the pH after the final injection.

**

Data not used to produce the histogram in Figure 6d.