Skip to main content
. Author manuscript; available in PMC: 2009 Nov 2.
Published in final edited form as: Radiology. 2001 Apr;219(1):101–107. doi: 10.1148/radiology.219.1.r01ap14101

Table 3.

Hippocampal ADC for distinction between controls vs. AD and MCI patients at a specificity of 80 %

Calculation AD vs. Control MCI vs. Control
Sensitivity 57 % (12 /21) 47 % (9 /19)
Specificity 80 % (44 /55) 80 % (44 /55)
Positive predictive value 52 % (12 /23) 45 % (9 /20)
Negative predictive value 83 % (44 /53) 82 % (44 /54)