Skip to main content
. 2009 Nov;7(6):555–558. doi: 10.1370/afm.1016

Table 1.

Characteristics of the Included Studies, With Nerve Conduction Study as Reference Standard

Characteristic Lee, 200314a,b Perkins, 200115a,c Shin, 200019d
Participants n (% women) 37 (46) 478 (34) 126 (54)
Age, mean, y 59 54 58
Population Unselected type 2 diabetic outpatients in Pusan, Korea a. 426 Unselected diabetic patients attending secondary and tertiary diabetic clinics, and recruited through advertisements
b. 52 Nondiabetic reference subjects in Toronto General Hospital/University Health Network, Canada
Consecutive diabetic patients referred to a secondary foot clinic in Seoul, Korea
Methods of monofilament testing
    Sites, No. and Location 10, Dorsal between base digit 1–2; ventral digit 1,3,5; MT heads 1,3,5; medial and lateral midfoot; heel 1, Hallux NR
    Threshold ≥ 5 of 10 incorrect (1 foot) a. ≥ 5 of 8 incorrect (both feet)
b. ≥ 2 of 8 incorrect (both feet)
NR
Sensitivity (95% CI) 93.1 (0.77–0.99) a. 40.9 (0.36–0.46)
b. 77.0 (0.72–0.81)
56.7 (0.44–0.69)
Specificity (95% CI) 100.0 (0.63–1.00) a. 96.2 (0.90–0.99)
b. 68.3 (0.58–0.77)
94.9 (0.86–0.99)
LR+ (95% CI) 16.5 (1.1–245.0) a. 10.6 (4.0–28.0)
b. 2.4 (1.8–3.2)
11.2 (4.0–34.0)
LR– (95% CI) 0.07 (0.02–0.26) a. 0.61 (0.56–0.67)
b. 0.34 (0.27–0.42)
0.46 (0.35–0.60)

CI=confidence interval; QUADAS = Quality Assessment of Diagnostic Accuracy Studies, LR = likelihood ratio; MT = metatarsal, NR = not reported.

a QUADAS limitation: selection criteria not clearly described.

b QUADAS limitation: test results possibly not interpreted without knowledge of the other test results.

c QUADAS limitation: withdrawals from study not clearly explained.

d QUADAS limitation: execution of index test and reference standard not described in sufficient detail.