Skip to main content
. 2009 Oct 30;65(Pt 11):1157–1161. doi: 10.1107/S1744309109037890

Table 1. Crystallographic data-collection and refinement statistics.

Values in parentheses are for the highest resolution shell.

Data-collection statistics  
 Space group P42212
 Unit-cell parameters (Å) a = b = 99.14, c = 229.06
 Resolution (Å) 50.0–4.7 (4.95–4.7)
Rmerge (%) 8.3 (40.7)
 Completeness (%) 91.0 (92.7)
I/σ(I) 10.4 (2.99)
 No. of reflections 21804 (3122)
 No. of unique reflections 5856 (817)
Molecular-replacement statistics  
 Resolution (Å) 15.0–4.7
 Two-body rigid-body refinement  
  Correlation coefficient (%) 68.2
   R factor (%) 52.3
 Seven-body rigid-body refinement  
  Correlation coefficient (%) 69.8
   R factor (%) 50.9

R merge = Inline graphic Inline graphic.

R = Inline graphic Inline graphic. The R factor is calculated on all reflections.