Skip to main content
. 2009 Sep 23;35(12):2130–2134. doi: 10.1007/s00134-009-1663-5

Table 2.

Changes in impedance during and after closed endotracheal tube suction compared to the baseline (zero) values

Infant no. Maximum impedance loss during suction Residual impedance loss after suction
Global ΔZ Region of interest (% of maximum global loss) Global ΔZ (% of max loss) Region of interest (% of residual global loss)
V D R L V D R L
1 −51 −31 (59) −20 (41) −24 (48) −26 (52) −5.1 (10) −4.5 (88) −0.6 (12) −3.7 (72) −1.5 (28)
2 −68 −39 (57) −29 (43) −33 (48) −35 (52) −2.3 (3) −2.3a 0.07a −1.2 (51) −1.1 (49)
3 −43 −15 (35) −28 (65) −24 (55) −19 (45) 6.2b 3.7 (60) 2.5 (40) 2.1 (34) 4.1 (66)
4 −62 −31 (50) −31 (50) −35 (57) −27 (43) −1.8 (3) 1.9a −3.7a −1.4 (76) −0.4 (24)
5 −58 −41 (70) −17 (30) −27 (46) −31 (54) 0.02 (0) 0.5a −0.4a −1.3a 1.3a
6 −67 −31 (46) −36 (54) −46 (69) −21 (31) −0.1 (0.2) −0.3a 0.2a −1.2a 1.1a
7 −34 −17 (50) −17 (50) −19 (57) −15 (43) −3.7 (11) −0.3 (7) −3.4 (92) −2.4 (65) −1.3 (35)
8 −40 −22 (55) −18 (45) −21 (52) −19 (48) −3.5 (9) −2.8 (81) −0.7 (19) −0.8 (23) −2.7 (77)
9 −59 −35 (60) −24 (40) −31 (52) −28 (48) −8.7 (15) −3.4 (39) −5.3 (61) −4.1 (47) −4.6 (53)
10 −49 −25 (51) −24 (49) −24 (49) −25 (51) −6.6 (13) −4.2 (63) −2.4 (37) −4.0 (61) −2.6 (39)
11 −48 −32 (66) −16 (34) −27 (56) −21 (44) 9.3b 2.3 (25) 7.0 (75) 3.5 (37) 5.8 (63)
Median −51 −31 (55) −24 (45) −27 (52) −25 (48) −2.3 (3) −0.3 −0.6 −1.3 −1.1

V Ventral, D dorsal, R right, L left

aRegions with volume loss and increase after endotracheal suction (percentages not shown because of the opposite regional values)

bImpedance stabilized at higher level after suction compared to baseline