TABLE 1.
Oxygen consumption kinetic parameters for the WT and Erv1p mutants
All of the experiments were carried out with 1 mm Erv1p proteins in 50 mm Tris buffer, pH 7.4, 150 mm NaCl, 1 mm EDTA at 25 °C. The error bars represent the standard errors (n = 3).
| Electron donor | Erv1p | kcat | Km | kcat/Km |
|---|---|---|---|---|
| s−1 | mm | m−1s−1 | ||
| 10 mm DTT | WT | 1.3 ± 0.1 | 57 ± 4 | 2.3 ± 0.2 × 104 |
| C30S/C33S | 1.5 ± 0.1 | 62 ± 5 | 2.4 ± 0.2 × 104 | |
| C130S/C133S | <0.1 | |||
| C159S/C176S | 0.8 ± 0.1 | 87 ± 8 | 9.2 ± 0.2 × 103 | |
| 3.5 mm TCEP | WT | 1.1 ± 0.1 | 27 ± 3 | 4.1 ± 0.3 × 104 |
| C30S/C33S | <0.1 | |||
| C130S/C133S | <0.05 | |||
| C159S/C176S | 0.7 ± 0.1 | 18 ± 2 | 3.9 ± 0.3 × 104 | |