Skip to main content
. 2009 Oct 28;16(12):1781–1788. doi: 10.1128/CVI.00248-09

TABLE 1.

IC data: descriptive statistics for quantitative resultsa

Sample No. of values reported No. of values used in analysesb Expected sample value (EU/ml)b Mean sample value (EU/ml)c IC %CV
S1 39 0 <15 <15
S2 39 35 30 32 23
S3 117 108 55 53 26
S4 117 107 85 74 25
S5 39 36 105 100 21
S6 39 37 105 109 36
S7 117 102 170 148 31
S8 117 85 275 230 29
CI 39 0 <15 <15
CII 39 37 49 49 18
CIII 39 38 94 85 17
a

Controls CI, CII, and CIII and samples S1, S2, S5, and S6 were tested one time per assay plate; whereas, samples S3, S4, S7, and S8 were tested three times per assay plate.

b

A result was included in the analysis if the reported value fell within the assay range of 15 to 480 EU/ml and the %CV did not exceed 25%. Results were excluded as follows: 78 values were <15 EU/ml, 15 values were >480 EU/ml, and 63 values had a %CV of >25%.

c

ELISA units/ml.