Skip to main content
. 2009 Nov 30;8:68. doi: 10.1186/1476-072X-8-68

Table 2.

Effect of data collection frequency and of programming the units to be turned off at night (23:00 to 05:00) on the battery life (Test I) of the Igot-U GT100 GPS data-loggers.

Average time (in hours) for battery depletion (range)

Time frequency Night-ON1 Night-OFF1
1 sec 4.5 (4.4 - 4.5) ND2
30 sec 26.7 (30.3) 34.1 (40.9)
1 min 28.9 (18.4 - 48.1) 42.6 (38.4 - 46.7)
2 min 57.1 (50.8 - 70.3) 60.3 (53.3 - 65.9)
2.5 min 68.5 (61.2 - 73.2) 71.8 (71.7 - 72.0)
3 min 66.3 (51.5 - 76.3) 90.4 (11.3 - 95.0)

1GPS units can be programmed to log positions only during the day. Night-ON represents units set to continuously collect positions whereas Night-OFF represented units set to collect positions only during the day and crepuscule (05:00 am to 9:00 pm).

2The night option was not tested because of the short battery life of units at this collection frequency.