Skip to main content
. 2009 Sep 25;297(6):H2206–H2219. doi: 10.1152/ajpheart.00348.2009

Table 2.

Characteristic network parameters obtained by model simulations of hemodynamics and oxygen distribution using experimental diameters and diameters after simulated adaptation with different metabolic signaling modes

Experimental Diameters Simulated Diameter Adaptation
Tissue Signaling Wall Signaling RBC Signaling
Network characteristics
    Verr 0.61 0.73 0.60 0.81
    Diaerr 0 0.50 0.38 0.68
    Hcerr 0.51 0.65 0.58 0.92
    OxDef, % 0.7 0.2 0.2 4.7
    Vol, nl 44 43 42 35
Optimized adaptation parameters
    km 1.30 0.80 0.64
    kc 1.52 1.60 2.17
    kp 0.90 0.35 0.65
    ks 3.24 2.51 1.89
    Pref, mmHg 115 95 92
    Q˙ref, nl/min 0.007 0.012 0.012
    Jref 4,822 4,925 5,537

See text for definitions of acronyms. For simulated adaptation, optimized values of adaptation parameters are given.