Table 2.

Results of sensitizer-wire/protein experiments with cytochrome P450cam and iNOS. Superscripts denote references. Subscripts: (a) distances inferred from [Re-Im-F9bp]+; (b) the heme was reduced using a flash/quench method; (c) the heme was reduced using a flash/quench method but a rate was not determined; (d) the heme was reduced directly from Ru(II)* or Re(I)*

Wire RRu-Fe (Å) Rate of Heme Reduction (s-1)
cytochrome P450cam [bpyRu-C11-Im]2+ NA NA
[bpyRu-C13-Im]2+ 21.2[2] 2×104 [1]b
[bpyRu-C9-Ad]2+ 21.4[2] NA
[bpyRu-C11-Ad]2+ 21.0[2] 2×104 [1]b
[bpyRu-C7-EB]2+ 19.5[2] 1×103 [3]b
[bpyRu-C9-EB]2+ 19.4[2] NA [3]c
[bpyRu-C10-EB]2+ 19.9[2] NA [3]c
[bpyRu-C11-EB]2+ 20.1[2] 2×104 [1]b
[bpyRu-C12-EB]2+ 20.5[2] NA [3]c
[bpyRu-C13-EB]2+ 20.6[2] NA [3]c
[bpyRu-F8bp-Im]2+ 22.1[2] 4.4×106 [6]d
[tmbpyRu-F8bp-Im]2+ 18.1[6] 2.8×107 [6]d
[Ru-F8bp-Ad]2+ 22.1[6] NA
[tmbpyRu-F9bp]2+ 17.0[6] NA
iNOS [Re-Im-F8bp-Im]+ 18.0[7]a 7×109 [8]d
[Re-Im-C3-F8bp-Im]+ 18.0[7]a 3×109 [8]d
[Re-Im-C8-ArgNO2]+ 25.5[10] > 1×106 [10]d
[Re-Im-F9bp]+ 18.0[7] NA
[tmbpyRu-F9bp]2+ 20.0[7] 2×107 [12]b