Table II. Correlation Coefficients and Regression Results for Dual-Tracer FDG (0 min.) + ATSM (10, 20 min.) Imaging Measures.

ATSM injected at 10min ATSM injected at 20min
FDG K1 y = 1.02x + 0.02 R = 0.99 y = 0.99x + 0.01 R > 0.99
FDG k2 y = 0.95x + 0.11 R = 0.99 y = 0.99x + 0.02 R = 0.99
FDG k1 y = 1.00x Š 0.01 R > 0.99 y = 1.00x Š 0.01 R > 0.99
FDG Knet y = 0.94x + 0.00 R > 0.99 y = 0.97x + 0.00 R > 0.99
FDG SUV y = 0.98x Š 0.01 R > 0.99 y = 0.99x - 0.00 R > 0.99
ATSM K1 y = 0.89x + 0.00 R = 0.98 y = 0.83x + 0.03 R = 0.98
ATSM k2 y = 0.41x + 0.38 R = 0.03 y = 0.11x + 0.31 R = 0.01
ATSM k3 y = 0.20x + 0.80 R = 0.22 y = 0.21x + 0.50 R = 0.25
ATSM Knet y = 0.33x + 0.05 R = 0.81 y = 0.30x + 0.02 R = 0.82
ATSM SUV y = 0.76x + 084 R = 0.90 y = 0.67x + 0.58 R = 0.92