Table 1.

Each subject’s notch frequency and notch depths for the threshold measures (SPL, FPL, and IPL) are provided. From the notch frequency, distance between the 4-mm probe microphone and TM was estimated as the 14 wavelength distance.

ID Notch (Hz) SPL notch depth (dB) FPL notch depth (dB) IPL notch depth (dB)
S1 5279 −9.90 −4.55 −4.54
S2 5282 −19.30 −10.05 −9.85
S3 6610 −10.90 4.65 5.35
S4 4734 −0.35 4.55 3.86
S5 6352 −15.20 3.35 4.31
S6 5856 −19.60 −6.60 −6.20
S7 5173 −16.30 −4.50 −3.87
S8 4097 −4.05 −2.20 −2.64
S9 6296 −12.75 −1.75 −0.91
S10 4749 −17.45 −8.20 −7.88
S11 6392 −15.90 −5.90 −5.02
S12 7484 −6.45 6.95 7.51
S13 5657 −6.85 4.45 4.46
S14 5992 −10.95 −0.50 0.17
S15 6105 −11.35 −2.70 −1.80
S16 5884 −10.35 4.10 4.23
S17 6524 −12.40 4.75 5.57
S18 7346 −10.40 4.50 5.13
S19 7658 −5.70 0.65 0.91
S20 7405 −16.2 −4.65 −4.65
S21 4828 −8.55 −5.15 −5.94
S22 4993 −4.95 1.7 1.63
Mean 5940.73 −11.18a −0.78 −0.46
Std. dev. 993.56 5.15 4.99 5.07
a

SPL notch depth (dB) was significantly different (p<0.05) from both FPL and IPL notch depths (dB).