. 2009 Dec 31;4:70. doi: 10.1186/1748-717X-4-70

Table 3.

Discrepancies in lumpectomy cavity (LC) volumes; in conformity index and in distances between centres of gravity of each LC volume when the study was restricted to CT slices containing surgical clips.

Volume of lumpectomy cavity - cm3 (n = 40) P* Conformity index Distance between gravity centres (mm)
ΔJ1-J2 Med
(min; max)
- 0.9
(-17.9; 13.1)
0.02 0.64
(0.36; 0.80)
2.2
(0.0; 11.9)

ΔJ1-E1 Med
(min; max)
1.5
(-4.5; 17.7)
0.007 0.65
(0.13; 0.82)
1.8
(0.5; 26.3)

ΔJ1-E2 Med
(min; max)
3.5
(-20.9; 24.5)
< 0.0001 0.57
(0.09; 0.77)
2.4
(0.6; 30.9)

ΔJ2-E1 Med
(min; max)
3.5
(-4.9; 22.8)
< 0.0001 0.57
(0.24; 0.86)
2.4
(0.7; 20.4)

ΔJ2-E2 Med
(min; max)
4.2
(-7.5; 27.1)
< 0.0001 0.55
(0.07; 0.88)
3.1
(1.3; 24.7)

ΔE1-E2 Med
(min; max)
1.6
(-27.4; 10.2)
< 0.0002 0.62
(0.38; 0.73)
2.51
(0.2; 10.0)

* p value for testing equality of volumes between physicians ( < 0.01 is significant).

ΔJ1-J2 = between J1 and J2. ΔJ1-E1 = between J1 and E1. ΔJ1-E2 = between J1 and E2. ΔJ2-E1 = between J2 and E1. ΔJ2-E1 = between J2 and E2. ΔE1-E2 = between E1 and E2.