Skip to main content
. Author manuscript; available in PMC: 2011 Feb 1.
Published in final edited form as: Biomaterials. 2009 Nov 4;31(6):1068. doi: 10.1016/j.biomaterials.2009.10.039

Table 3.

Contact Activation of FXII by Incubation with Physical Mixtures of Hydrophilic and Hydrophobic Procoagulants

FXII
Lot
w/w Fraction
Hydrophilic
Hypothetical
Contact Angle (θ)
(Degrees)
Hypothetical
τno
(dyne/cm)
Average FXIIa Solution
Concentration ((PEU/ml)
× 10−2, N=2)
Average
FXIIa Yield
(%, N=2)
1 0.0 117.57 −33.31 3.89 ± 0.61 1.76 ± 0.28
0.1 108.45 −22.78 4.73 ± 0.73 2.14 ± 0.33
0.2 99.80 −12.25 3.32 ± 0.53 1.50 ± 0.24
0.3 91.37 −1.72 3.38 ± 0.54 1.53 ± 0.25
0.4 82.97 8.80 3.48 ± 0.56 1.57 ± 0.25
0.5 74.41 19.32 3.59 ± 0.57 1.62 ± 0.26
0.6 65.48 29.85 4.64 ± 0.72 2.10 ± 0.33
0.7 55.86 40.38 3.49 ± 0.56 1.58 ± 0.25
0.8 44.97 50.91 3.31 ± 0.53 1.50 ± 0.24
0.9 31.38 61.44 3.97 ± 0.63 1.80 ± 0.28
1.0 0.00 71.97 3.26 ± 0.53 1.48 ± 0.24
2 0.0 118.08 −33.87 3.34 ± 0.53 1.51 ± 0.24
0.1 110.59 −25.31 3.35 ± 0.54 1.52 ± 0.24
0.2 101.62 −14.50 3.39 ± 0.54 1.54 ± 0.25
0.3 92.94 −3.69 2.57 ± 0.43 1.16 ± 0.19
0.4 84.32 7.11 3.21 ± 0.52 1.45 ± 0.23
0.5 75.58 17.92 3.03 ± 0.49 1.37 ± 0.22
0.6 66.47 28.73 2.49 ± 0.41 1.13 ± 0.19
0.7 56.67 39.54 3.25 ± 0.52 1.47 ± 0.24
0.8 45.60 50.35 3.46 ± 0.55 1.57 ± 0.25
0.9 31.80 61.16 2.42 ± 0.40 1.10 ± 0.18
1.0 0.00 71.97 2.52 ± 0.42 1.15 ± 0.19

Notes: Hydrophilic glass particles (n = 6) mixed with hydrophobic glass particles (n = 12) listed in Table 1. Total procoagulant mass = 100 mg. Hypothetical θ and τno computed from a linear combination rule (Appendix B). Error in FXIIa concentration is standard deviation of N = 3 measurements with error in percent yield computed by propagation of error. Results obtained with plasma lot II.