Skip to main content
. Author manuscript; available in PMC: 2010 Aug 11.
Published in final edited form as: Circulation. 2009 Jul 27;120(6):477. doi: 10.1161/CIRCULATIONAHA.108.838821

TABLE 5.

Prevalence and diagnostic utility of ECG Features Based on Combination of Criteria

Parameter Prevalencea Diagnostic Utilityb
ARVD
(n=100)
Controls
(n=57)
Sensitivity Specificity
No RBBB
   Depolarization Criteria (QRSd > 110 ms, TAD, Epsilon wave) 37(54) 3(11) 54 (42–67) 89 (71–98)
   Repolarization Criteria (TWI thru V3, TWI in Inferior leads (2 out of 3) 52(76) 2(7) 76 (65–86) 93 (76–99)
  (Combination of Repolarization and Depolarization Criteria)
   1 Criterion 60 (88) 5 (19) 88 (78–95) 81 (62–94)
   2 Criteria 29 (43) 0 (0) 43 (31–55) 100 (87–100)
IRBBB
   Depolarization Criteria (QRSd > 110 ms, TAD, Epsilon wave) 13(87) 8(36) 87 (60–98) 64 (41–83)
   Repolarization Criteria (TWI thru V3, TWI in Inferior leads (2 out of 3) 13(87) 1(5) 87 (60–98) 95 (77–100)
  (Combination of Repolarization and Depolarization Criteria)
   1 Criterion 15 (100) 9 (41) 100 (78–100) 59 (36–79)
   2 Criteria 11 (73) 0 (0) 73 (45–92) 100 (85–100)
CRBBB
   Depolarization Criteria (r'/s amplitude < 1) 15(88) 1(13) 88 (64–99) 88 (47–100)
   Repolarization Criteria (TWI thru V4, TWI in inferior leads (2 out of 3))* 13(76) 2(25) 76 (50–93) 75 (35–97)
  (Combination of Repolarization and Depolarization Criteria)
   1 Criterion 17 (100) 3 (38) 100 (80–100) 63 (24–91)
   2 Criteria 11 (65) 0 (0) 65 (38–86) 100 (63–100)

Indicates P<0.01

*

Indicates P<0.05

a

Data expressed as frequency (%)

b

Data expressed as point estimate (95% Confidence Interval)