TABLE 1.
No. of samples | Resulta by the following assay: |
|||||
---|---|---|---|---|---|---|
Abbott m2000 | Roche CT | Gen-Probe AC2 | Arbiter test (ACT assay) | Reference standardb | In-house mutant plasmid PCR | |
28 | + | + | + | + | + | + |
91 | + | + | + | + | + | − (3 NT) |
7 | + | − | + | + | + | + |
15 | + | − | + | + | + | − |
1 | − | + | + | + | + | + |
1 | − | + | + | + | + | NT |
4 | − | − | + | + | + | − |
1 | − | + | − | + | + | NT |
2 | + | − | − | − | − | ND |
1 | − | − | + | − | − | ND |
1,481 | − | − | − | − | − | ND |
+, positive, −, negative; ND, not done; NT, nontypeable.
The reference standard is defined as positive results for a sample by any two of the four commercial assays.