Skip to main content
. 2008 Oct 29;19(3):722–730. doi: 10.1007/s00330-008-1200-x

Table 2.

Accuracy, number of attempts to gain access to the glenohumeral joint, injected volume and leakage of contrast media with four different image-guided approaches

  Overall FLa FLp USa USp FL(a + p) US(a + p)
Number of patients (N) 100 25 25 25 25 50 50
Intra-articular injection 100 (100%) 25 (100%) 25 (100%) 25 (100%) 25 (100%) 50 (100%) 50 (100%)
1st attempt 83 (83%) 19 (76%) 17 (68%) 24 (96%) 23 (92%) 36 (72%) 47 (94%)
2nd attempt 14 (14%) 5 (20%) 6 (24%) 1 (4%) 2 (8%) 11 (22%) 3 (6%)
3rd attempt 3 (3%) 1 (4%) 2 (8%) 0 (0%) 0 (%) 3 (6%) 0 (0%)
No leakage 49 (49%) 8 (32%) 13 (52%) 16 (64%) 12 (48%) 21 (42%) 28 (56%)
Minimal leakage noncompromising 24 (24%) 12 (48%) 3 (12%) 4 (16%) 5 (20%) 15 (30%) 9 (18%)
Massive leakage noncompromising 27 (27%) 5 (20%) 9 (36%) 5 (20%) 8 (32%) 14 (28%) 13 (26%)
Minimal leakage compromising 0 (0%) 0 (0%) 0 (0%) 0 (0%) 0 (0%) 0 (0%) 0 (0%)
Massive leakage compromising 0 (0%) 0 (0%) 0 (0%) 0 (0%) 0 (0%) 0 (0%) 0 (0%)
Minimal injected volume (ml) 5.0 10.0 9.0 5.0 10.0 9.0 5.0
Maximal injected volume (ml) 20.0 20.0 20.0 20.0 20.0 20.0 20.0
Mean injected volume (ml) 15.6 14.5 14.9 14.6 18.6 14.7 16.6
Local anaesthetics No Yes No No
Needle size (gauge) 20 18 21 21

USa: US-guided anterior injection, USp: US-guided posterior injection, FLa: fluoroscopic-guided anterior injection, FLp: fluoroscopic-guided posterior injection, FL (a + p): fluoroscopic-guided anterior and posterior approach, US (a + p): US-guided anterior and posterior approach