TABLE 2.

Tabulation of the experimentally determined values of the speed of sound, the attenuation, and the nonlinear parameter B/A for all isopropanol concentrations. Also shown is the standard deviation associated with B/A as well as the percent error of B/A. The average uncertainty associated with measuring B/A was found to be 4.4%.

Isopropanol Concentration Speed of Sound (m/s) Attenuation (cm−1) Nonlinear Parameter B/A Standard Deviation of B/A Percent Error (S.D. / Mean) * 100%
0% 1490.40 4.04 * 10−3 5.00 - -
5% 1527.60 5.26 * 10−3 4.80 0.09 1.8%
10% 1562.70 1.31 * 10−2 4.64 0.13 2.8%
15% 1597.40 1.58 * 10−2 4.85 0.26 5.3%
20% 1622.00 2.27 * 10−2 5.24 0.23 4.4%
25% 1630.30 6.72 * 10−2 6.12 0.11 1.8%
30% 1610.50 0.183 7.04 0.26 3.7%
40% 1549.50 0.351 9.71 1.08 11%
60% 1415.80 0.240 11.4 0.84 7.4%
80% 1295.20 9.75 * 10−2 11.9 0.23 1.9%
100% 1162.40 4.22 * 10−2 11.8 0.38 3.3%
Average percent error for all of the measurements of the nonlinear parameter B/A: 4.4%