Skip to main content
. 2010 Jan 15;11(1):126–132. doi: 10.1208/s12249-009-9365-4

Table IV.

Results of the External Validation of the Statistical Model ROUND to Predict Ease of Subdivision of Round-Scored Tablets

Tablet In vivo ease of subdivision Compliance with requirement Ease of subdivision predicted Compliance with requirement Prediction of compliance
H 0.912 Complies 0.782 Out of spec False
K 0.813 Complies 0.878 Complies Correct
T 0.571 Out of spec 0.512 Out of spec Correct
V 0.905 Complies 0.937 Complies Correct
W 0.524 Out of spec 0.494 Out of spec Correct

Also shown: correctness of prediction of the model in terms of compliance with the requirement: ease of subdivision NLT 0.800