Skip to main content
. 2010 Jan 9;11(1):103–112. doi: 10.1208/s12249-009-9363-6

Table III.

The Kinetic Parameters Obtained by Nonlinear Regression of Nonisothermal Data Using Eq. 12 and the Constant Value of the Apparent Activation Energy (152.3 kJ mol−1) for the Third Degradation Stage of Folnak® Sample

β (°C min−1) 3rd Folnak® degradation stage
n ln A, A (min−1) RSS
2.5 1.59 35.31 0.00360
5 2.21 35.61 0.00397
10 1.85 35.53 0.00325
20 1.98 35.58 0.00276

Values of residual sum of squares (RSS) at the corresponding heating rates are also presented in the same table