Skip to main content
. Author manuscript; available in PMC: 2011 May 1.
Published in final edited form as: J Electrocardiol. 2010 Jan 25;43(3):251–259. doi: 10.1016/j.jelectrocard.2009.12.009

Table 2.

Unadjusted Conditional Logistic Regression for SCD.

OR
(95% CI)
p-value
Full Cohort (N=146, 49 SCD)
Lower half of VPCs (≤26, N=58,
9 SCD)
1.0
Upper half of VPCs (>30, N=88,
40 SCD)
4.61
(1.96–10.84)
<0.001
Cohort with HRT (N=144, 48 SCD)
Normal HRT 1.0
Abnormal HRT 2.60
(1.16–5.60)
0.019
Cohort with Usable TWA in Ch 2 (N=133, 46 SCD)
TWA>37 µV in Ch2 (N=35, 14
SCD)
2.78
(1.08–7.14)
0.034
Cohort with Usable Frequency Domain HRV (N=127, 37 SCD)
Normalized LF power 0.96
(0.92–0.99)
0.015
DFA1 0.08
(0.010–0.6)
0.012
DFA1 ≥1.015 (N=82) 1.0
DFA1 <1.015 (N=45) 5.61
(2.05–15.3)
0.001
Cohort with Usable TWA in Ch 2 and Usable Frequency Domain
HRV (N=127, 33 SCD)
TWA>37 µV in Ch2 3.47
(0.95–12.6)
0.053

Table Legend: See Legend Table 1.