Skip to main content
. 2010 Mar 10;17(5):813–817. doi: 10.1128/CVI.00489-09

TABLE 1.

Performance of the Enferplex TB multiplex immunoassay on field animals

Enferplex TB cutoff level Sensitivitya Specificityb
5 77.1 (67.4, 85.0) 100 (96.1, 100)
4 79.2 (69.7, 86.8) 97.9 (92.4, 99.7)
3 81.3 (72.0, 88.5) 94.6 (87.9, 98.2)
2 82.3 (73.1, 89.3) 91.4 (83.8, 96.2)
1 86.5 (78.0, 92.6) 79.6 (70.0, 87.23)
a

Measured for 96 SICCT reactor animals, with visible lesions and positive M. bovis cultures. Both sensitivity and specificity are expressed as percentages, with 95% confidence intervals in parentheses.

b

Measured for 93 skin test-negative cattle from TB-free herds.