Table 1.
Dose Level | Radiation Therapy | ||
---|---|---|---|
Original Protocol | Amended Protocol | ||
1 | 75.25 Gy / 35 fxs (2.15 Gy per fraction) | Cohort 1 | |
2 | 80.5 Gy / 35 fxs (2.3 Gy per fx) (escalation dose†) | 74 Gy / 37 fxs (2.0 Gy per fx) (de-escalation dose) | Cohort 2 (MTD) |
3 | 79.5 Gy / 30 fxs (2.65 Gy per fx) (escalation dose†) | 70 Gy / 35 fxs (2.0 Gy per fx) (de-escalation dose‡) | |
4 | 75 Gy / 25 fxs (3.0 Gy per fx) (escalation dose†) | n/a |
Amended since dose level 1 was too toxic.
Unnecessary since dose level 2 was deemed safe.