Skip to main content
. 2010 Mar 19;76(10):3343–3351. doi: 10.1128/AEM.02668-09

TABLE 1.

Experimental test matrixa

CD generation type (run no.) CD concn (ppmv) Average RH (%)b Coupon and BI removal times (h)c
Sabre (SB05001001) 500 80 0.5, 1, 3, 5, 10
Sabre (SB05001002) 500 77 0.5, 1, 3, 5, 10
Sabre (SB10000701) 1,000 78 0.5, 1, 3, 5, 7
Sabre (SB10000801) 1,000 79 0.5, 1, 3, 5, 8
Sabre (SB10000802) 1,000 78 0.5, 1, 3, 5, 8
Sabre (SB10000901) 1,000 76 1, 3, 5, 7, 9
Sabre (SB15000501) 1,500 80 0.5, 1, 2, 3, 5
Sabre (SB15000502) 1,500 81 0.5, 1, 2, 3, 5
Sabre (SB15000601) 1,500 77 0.5, 1, 2, 3, 6
Sabre (SB30000701) 3,000 74 0.5, 1, 2, 3, 7
Sabre (SB30000702) 3,000 75 0.5, 1, 2, 3, 7
Sabre (SB30000703) 3,000 75 0.5, 1, 2, 3, 5
Sabre (SB30000901) 3,000 76 1, 3, 5, 7, 9
Sabre (SB30000902) 3,000 75 1, 3, 5, 7, 9
CSI (CSI05001003) 500 80 0.5, 1, 3, 5, 10
CSI (CSI05001004) 500 78 0.5, 1, 3, 5, 10
CSI (CSI05001005) 500 78 0.5, 1, 3, 5, 10
CSI (CSI30000901) 3,000 75 1, 3, 5, 7, 9
CSI (CSI30000902) 3,000 75 1, 3, 5, 7, 9
a

The chamber temperature was set at 25°C.

b

Standard deviations for mean temperature and RH were <1°C and <3%, respectively.

c

Time zero is defined as the start of the sterilization phase of the fumigation.