Skip to main content
. 2010 Apr 28;15(2):027011. doi: 10.1117/1.3374180

Table 2.

Geometric parameters of the six microsphere sensor models used in simulations. The sensor names in the simulations are D100S100, D60S100, D20S100, D60S60, D20S60, and D20S20, where the values following the D and S correspond to the diameter and the center-to-center spacing between two adjacent spheres for each case given below, respectively.

D (μm) S (μm) Packing efficiency
100 100 74.05%
60 100 15.99%
20 100 0.59%
60 60 74.05%
20 60 2.74%
20 20 74.05%