Skip to main content
. 2010 Jun 2;98(11):2420–2431. doi: 10.1016/j.bpj.2010.02.033

Figure 8.

Figure 8

AP characteristics in the rabbit PF and ventricular cell models. (A) Simulation results (bars) and experimental data from rabbit (symbols): (i) APD, (ii) dV/dtmax, (iii) MDP, and (iv) APA. See Table S1 for the sources of experiment data. (B) APD alternans (top) and restitution curves (bottom) simulated using the PF (left) and Epi (right) cell models; simulated restitution curves (solid circles) are compared with experimental data (open symbols) from rabbit (6,20).