Skip to main content
. 2010 Jun;81(3):211–218. doi: 10.1016/j.mimet.2010.03.025

Table 3.

Comparison between TaqMan MGB assay-calculated mycoplasmal loads in artificially contaminated bronchoalveolar lavage fluids and inoculated CFU counts.

Inoculateda (CFUreaction) C305
O326
2022
Loadreactionb Δ(%)c Loadreactionb Δ(%)c Loadreactionb Δ(%)c
7 × 106 5.52 × 106 (± 3.72 × 105) − 21.08 4.93 × 106 (± 3.76 × 105) − 29.61 5.23 × 106 (± 8.94 × 105) − 25.23
7 × 105 5.94 × 105 (± 3.47 × 104) − 15.16 5.74 × 105 (± 2.58 × 104) − 18.07 5.57 × 105 (± 1.03 × 105) − 20.38
7 × 104 6.19 × 104 (± 5280) − 11.64 6.41 × 104 (± 5180) − 8.50 6.51 × 104 (± 3801) − 7.03
7 × 103 6524 (± 1260) − 6.80 6974 (± 250.7) − 0.37 6864 (± 339.2) − 1.94
a

CFU counts present in 2.5 μl of bronchoalveolar lavage fluids contaminated artificially with 10-fold diluted suspensions of the three strains C305, O326 and 2022.

b

Mycoplasmal loads obtained by applying the formula loadreaction = 1.3494 × 1012 × e− 0.63539 × Ct generated by the linear regression of the standard curve from the M. mycoides subsp. mycoides SC-specific TaqMan MGB assay. Four data sets for each strain and each dilution were used.

c

Percent difference between calculated mycoplasma loads and inoculated CFU counts.