Skip to main content
. 2009 Dec 23;7(48):1105–1118. doi: 10.1098/rsif.2009.0516

Table 1.

Grid covergence index (GCI) and particle number test.

no. grid independence tests GCI (u), % droplet/aerosol particle size number of tested droplets/aerosol particles relative error, % (0.3 µm) relative error, % (0.5 µm) relative error, % (1 µm) relative error, % (2 µm) relative error, % (10 µm) relative error, % (20 µm)
case 0 amount of grids (1): 99 123 amount of grids (2): 208 493 3.1 0.3, 0.5, 1, 2, 10 and 20 µm 40 000; 80 000; 120 000 0.30 0.18 0.06 0.24 0.10 0.04
amount of grids (2): 208 493 amount of grids (3): 320 930 3.0
case 1 amount of grids (1): 102 525 amount of grids (2): 208 493 4.7 0.08 0.14 0.08 0.11 0.04 0.09
amount of grids (2): 208 493 amount of grids (3): 301 616 5.2
case 2 amount of grids (1): 97 016 amount of grids (2): 191 823 4.2 0.20 0.44 0.58 0.09 0.11 0.03
amount of grids (2): 191 823 amount of grids (3): 311 229 4.3
case 3 amount of grids (1): 98 050 amount of grids (2): 203 158 5.0 0.14 0.12 0.05 0.05 0.02 0.02
amount of grids (2): 203 158 amount of grids (3): 320 973 4.2
case 4 amount of grids (1): 101 592 amount of grids (2): 209 666 3.3 0.26 0.31 0.07 0.18 0.16 0.11
amount of grids (2): 209 666 amount of grids (3): 301 783 5.2