Skip to main content
. Author manuscript; available in PMC: 2011 Jan 1.
Published in final edited form as: IEEE Trans Inf Technol Biomed. 2009 Oct 30;14(1):166–172. doi: 10.1109/TITB.2009.2034845

TABLE III.

THE RESULTS OF COMBINING SAI ABNORMALITY CONDITIONS AND PROPSOED SVD PROJECTION METHOD FOR VALID ABP BEAT DETECTION

Method FPR TPR PPV NPV
SVD projection 0.0769 0.9906 0.9851 0.9500
SVD projection +SAI condition (a) 0.0769 0.9905 0.9851 0.9499
SVD projection +SAI condition (b) 0.0449 0.9905 0.9912 0.9515
SVD projection +SAI condition (c) 0.0402 0.9905 0.9921 0.9514
SVD projection +SAI condition (d) 0.0759 0.9905 0.9853 0.9500
SVD projection +SAI condition (e) 0.0589 0.9669 0.9883 0.8466
SVD projection +SAI condition (f) 0.0765 0.9847 0.9851 0.9215
SVD projection +SAI condition (g) 0.0722 0.9654 0.9856 0.8389
SVD projection +SAI condition (h) 0.0722 0.9795 0.9858 0.8978
SVD projection +SAI condition (i) 0.0769 0.9901 0.9851 0.9480
SVD projection +SAI conditions (a) to (d) 0.0392 0.9905 0.9923 0.9515