Skip to main content
. 2010 Apr 14;103(6):3535–3546. doi: 10.1152/jn.00956.2009

Table 1.

Model parameters

Models Parameters Varied Values
Neural Range of recruitment threshold Yes 30, 5
Minimum firing rate No 8 Hz
Excitatory drive-firing rate gain No 1
Peak firing rate for first motor unit No 45 Hz
Peak firing rate difference No 10 Hz
Coefficient of variation in inter-spike interval No 0.2
Synchronization: fraction of reference spikes Yes 0, 0.061
Synchronization: fraction of test units Yes 0, 0.061
Muscle Range of peak forces No 100
Longest contraction time No 90 ms
Range of contraction times No 3
EMG Surface-recorded action potential duration Yes 5, 20 ms
Surface-recorded action potential magnitude Yes All equal, proportional to peak force

The nominal parameter set is shown in bold. The sensitivity of the model to each of the varied parameters was examined by changing that parameter alone while keeping the other parameters at their nominal value.