Table 4.
Method | T2 | MBF (mL/g/min) |
MBV (mL/g) |
OEF | MVO2 (μmol/g/min) |
T2sen* | |
---|---|---|---|---|---|---|---|
T2prep | Rest | 44 (6) | 0.89 (0.36) | 0.06 (0.02) | 0.73 (0.05) | 5.2 (1.7) | |
Aden | 49 (5)† | 2.97 (0.75)† | 0.10 (0.02)† | 0.37 (0.05)† | 9.2 (2.4) ξ | 4.8(5.1) | |
TSE | Rest | 55 (4)†† | 0.73 (0.05) | 5.2 (1.7) | |||
Aden | 59 (4) † | 0.41(0.14)† | 10.4 (5.1) | 3.2(2.9) |
OEF at rest are values of coronary sinus in Table 2
MBF and MBV were calculated from the first-pass perfusion imaging data sets.
*T2sen or T2 sensitivity = percentage of T2 change/100% increase in MBF
Aden = Adenosine vasodilation
†P < 0.01 for comparison between rest and adenosine.
ξ P < 0.05 for comparison between rest and adenosine.
††P < 0.05 for comparison between T2prep and TSE methods.