Weight-adjusted means and standard deviations of muscle contractile properties within each group during elicited contractions of the extensor digitorum longus.

Maximum
twitch force (g)
Twitch contraction
time (ms)
Half decay
time (ms)
Tetanic force (g) Fatigue index (%)





Variable M SD M SD M SD M SD M SD
Young 48.84 14.1 21.04 2.9 67.24 15.0 162.17a 38.9a 29.32 9.0
Old 33.28 8.3 20.06 1.8 65.37 11.6 97.77 33.4 34.56 9.0
F (dfs) 3.38 (1, 10) 0.32 (1, 10) 0.04 (1, 10) 5.78 (1, 10) 0.61 (1, 10)

Note. Group means, standard deviations, F values (and degrees of freedom [dfs]) for analyses of covariance are shown.

a

Significantly different (p < .05).