Table 1.
Initial Conditions | Maximum Error | |
---|---|---|
substrate (s0) | complex (c0) | σ [%] |
0.999 | 0.001 | ±14.0% |
0.990 | 0.010 | ±13.0% |
0.900 | 0.100 | ±8.5% |
0.800 | 0.100 | ±8.0% |
0.800 | 0.200 | ±5.0% |
0.700 | 0.300 | ±2.5% |
0.600 | 0.400 | ±0.5% |
Results of the model invalidation of the Michaelis-Menten mechanism. For each choice of initial conditions (concentration of substrate and complex), we report the largest error σ (in percentage) for which the resulting uncertain measurements allow to invalidate the Michaelis-Menten model.