Skip to main content
. 2009 May 26;35(4):471–480. doi: 10.1007/s00261-009-9539-2

Table 1.

Pancreatic multidetector row computed tomography (MDCT) protocol at UCLA

MDCT generation 16 row 64 row
Contrast 125 mL of 350 mg I/mL contrast agent infused at 3 cc/s
Scan timing
Pancreatic phase (PP)
    Fixed delay 50 s 55 s
    Bolus tracking 150 HU trigger + 25 s 150 HU trigger + 30 s
Hepatic phase (HP)
    Fixed delay 70 s 75 s
    Bolus tracking End of PP + 10 s End of PP + 10 s
Scan volume Diaphragm to iliac crests Diaphragm to iliac crests
Scan direction Cranial to caudal Cranial to caudal
Collimation (mm) PP: 0.75, HP: 1.5 PP: 0.6, HP: 1.5
Table feed/rotation (mm) PP: 12, HP: 24 PP: 38, HP: 76
Rotation time (s) 0.5 0.5
KVp 120 120
MAs 200–250 200–250
Image reconstruction
    Routine (thickness/interval) (mm) PP axial: 2/2 PP axial: 2/2
PP coronal: 2/1 PP coronal: 2/1
PP sagittal: 2/2 PP sagittal: 2/2
HP axial: 5/2.5 HP axial: 5/2.5
    Optional (thickness/interval) (mm) PP axial: 1/1 PP axial: 1/1