Skip to main content
. 2010 May-Jun;63(3):212–224. doi: 10.4212/cjhp.v63i3.917

Table 5.

Stability of Clindamycin during Storage in Accufuser Elastomeric Infusion Device, Expressed as Percentage of Original Concentration Remaining (Mean ± SD)*

Study Day Nominal 1 mg/mL
Nominal 12 mg/mL
D5W
NS
D5W
NS
23°C 4°C 23°C 4°C 23°C 4°C 23°C 4°C
Observed initial concentration (mg/L) 0.72 ± 0.05 0.76 ± 0.06 0.77 ± 0.11 0.76 ± 0.09 9.24 ± 0.93 8.77± 0.28 8.92 ± 0.04 9.62 ± 0.49
1 104.0 ± 1.9 102.6 ± 2.8 102.8 ± 1.7 103.2 ± 1.9 102.8 ± 2.9 101.4 ± 2.8 102.4 ± 2.6 101.8 ± 4.8
2 102.7 ± 1.4 102.0 ± 2.1 101.8 ± 1.2 102.3 ± 1.3 102.2 ± 2.8 104.1 ± 1.5 100.6 ± 0.9 100.2 ± 2.8
7 104.9 ± 1.4 104.6 ± 2.1 104.1 ± 1.7 103.9 ± 2.0 100.9 ± 2.9 100.2 ± 3.3 99.4 ± 0.6 99.2 ± 4.8
14 104.3 ± 3.1 104.5 ± 0.7 101.2 ± 2.4 100.7 ± 3.4
21 103.0 ± 1.6 103.7 ± 1.5 99.0 ± 1.1 99.1 ± 5.3

Degradation rate (%/day) 0.501 0.108 0.465 0.127 –0.043 –0.107 –0.230 –0.055
T–90% (days) 23.2 110.3 23.7 94.2 269.6 110.2 48.4 193.3

Fastest degradation rate§
  Lower limit of 95% CI (%/day) 0.891 0.121 0.469 0.076 1.274 0.360 0.230 0.198
  T–90% (days) 11.2 82.9 21.3 132.3 7.8 27.8 43.4 50.4

Estimated % remaining with storage
  13 days at 4°C + 24 h at 23°C 97.5 98.5 94.0 97.2
  21 days at 4°C + 24 h at 23°C 96.6 97.9 91.2 95.6

CI = confidence interval, D5W = dextrose 5% in water, NS = normal saline (0.9% sodium chloride), SD = standard deviation.

*

Each value was based on duplicate determination of 3 samples. The percent remaining was based on the observed concentration on day 0 (100%).

The degradation rate was determined by linear regression of the percent remaining on each study day.

T–90% is the time for the concentration to decline by 10% (i.e., time to reach 90% of initial concentration), as determined from the degradation rate.

§

Fastest degradation rate and T–90% were based on the lower 95% confidence limit of the regression-determined slope.

Using the fastest observed degradation rates determined by regression (95% CI), calculations were completed for a solution stored in an Accufuser elastomeric infusion device for 13 or 21 days, followed by storage for an additional period at room temperature (23ºC).