. 2000 Oct 13;4(6):369–376. doi: 10.1186/cc720

Table 1.

Tidal lung and tidal oesophageal volume, airway and oesophageal peak pressure for the intubating laryngeal mask and laryngeal tube and both self inflating bags

Laryngeal tube/
mask characteristics Peak Paw (cmH2O) Peak Poesoph (cmH2O) VT lung (ml) VT oesophagus (ml)
ILMA (before endotracheal intubation)
1100 ml bag 18 ± 2 0 674 ± 27 0
1500 ml bag 21 ± 2 0 790 ± 33* 0
ILMA (after endotracheal intubation)
1100 ml bag 25 ± 2* 0 623 ± 26 0
1500 ml bag 30 ± 3 0 741 ± 33* 0
Laryngeal tube
1100 ml bag 25 ± 2 0.1 ± 0.1 666 ± 31 0
1500 ml bag 27 ± 2 0.4 ± 0.4 752 ± 46 0

Data are expressed as mean ± standard error of the mean. Paw, airway pressure; Poesoph, oesophageal pressure; VT, tidal volume. *P < 0.05, versus 1100 ml self-inflating bag.