TABLE 6.

Multilevel adjusted difference in fluoroscopy time by trainee involvement

Factor Difference in fluoroscopy time %(95% CI)
Less-fluoroscopy procedures Fluoroscopy-intense procedures
Time handling duodenoscope
  0% Reference: 100% Reference: 100%
  1%–50% +112 (98–128) +82 (68–99)
  51%–99% +60 (48–73) +41 (28–56)
  100% +14 (4–25) +9 (−4–22)

CI, Confidence interval.