TABLE 7.

Multilevel adjusted odds ratios for fluoroscopy time ≥ 20 minutes by trainee involvement

Factor Odds ratio (95% CI)
Less-fluoroscopy procedures Fluoroscopy-intense procedures
Time handling duodenoscope
  0% Reference 1.0 Reference 1.0
  1%–50% 1.5 (1.0–2.4) 1.9 (1.2–2.9)
  51%–99% 0.7 (0.4–1.3) 0.9 (0.5–1.7)
  100% 0.2 (0.1–0.7) 0.0 (0.0–0.0)*

CI, Confidence interval.

*

Estimates did not converge, owing to limited size in this stratum.