Skip to main content
. Author manuscript; available in PMC: 2010 Jul 20.
Published in final edited form as: IEEE Trans Biomed Eng. 2009 Jun 16;57(2):220–237. doi: 10.1109/TBME.2009.2024928

TABLE I.

Evaluation of Inverse Solutions of Annulus Simulation Shown in Fig. 3

Noise Level Mesh A Mesh B Mesh C

Mean RE Noise Free 14.80% 10.99% 9.65%
30dB 15.10% 12.38% 12.20%
20dB 20.29% 19.75% 19.09%

λ Noise Free 0.0019 0.0007 0.0003
30dB 0.0027 0.0015 0.0014
20dB 0.0144 0.0128 0.0140

MGL Error Noise Free 1 1 1
30dB 0.9 0.54 0.42
20dB 0.70 0.66 0.56

The data represent the arithmetic average of 50 repeated simulations. White noise of 30 and 20 dB SNR is added to the torso-surface measurements before solving the inverse problem. MGL: maximum gradient location in the vector of the inverse solution.